I. Overview

With the more and more extensive use of cathodic protection technology for buried steel pipelines, the stability of the cathodic protection system has also attracted much attention.

However, electromagnetic interference is ubiquitous in real production life, and the influence of electromagnetic interference on pipeline cathodic protection system also exists. Because electromagnetic interference causes cathodic protection function failure, accelerated corrosion, damage to the applied current equipment cases are common, so the solution to the interference problem has become one of the very important issues in the cathodic protection system.

Usually, the solution of electromagnetic interference is to install discharge device on the pipeline, which can effectively solve the electromagnetic interference problem and limit the pipeline potential to a reliable level. However, there are some problems with the existing current discharge device, for example, it can only tolerate electromagnetic interference with a relatively small amplitude, and it cannot solve the interference of strong energy such as direct lightning current and induced lightning current.

Solid state decoupler can well solve the high voltage line fault ground short-circuit current, high voltage line on the upper end of the lightning line by lightning introduction of ground current, train through the railroad when the stray current. This product can protect the over-voltage or over-current generated by the above situations on the cathodic protection of pipelines, prevent pipelines from electromagnetic interference and aggravate corrosion, and play an effective role in protecting pipeline equipment.


II. Cited standards

·IEC61643.1-2005 

“Surge Protectors for Connection to Low Voltage Distribution Systems Part 1: Performance Requirements and Test Methods”

·NACE RP0177 

“Measures to mitigate the effects of alternating current and lightning on metal structures and corrosion control systems”

·GB18802.1-2011/IEC61643-1 

"Surge Protectors (SPD) for Low Voltage Distribution Systems Part 1: Performance Requirements

and Test Methods".

·GB/T19271.1

 "Protection against Lightning Electromagnetic Pulse (EMP) Part 1: General Principles".

·GB50057  Lightning Protection Design Code for Buildings

·GB50251  “Gas Transmission Pipeline Engineering Design Code”

·GB50253  “Design Code for Oil Pipeline Engineering”

·GB4208  “Case Protection Level (IP Code)”

·GB/T2423  “Environmental Tests for Electrical and Electronic Products”

·SY/T0032-2000  “Technical Standard for AC Discharge Protection of Buried Steel Pipelines”


III.Performance Parameters

No.

Item

Technical parameters

1

Rated isolation voltage Un

-2.0V/+2.0V

2

Lower leakage current Un

≤10mA

3

Lower leakage current Un 0.75 times

≤1mA

4

Rated lightning impact current capacity (8/20μs)

100kA

5

AC fault current

≥3500A

6

AC impedance

<10mΩ

7

 Steady state AC current rating

≤45A

8

Operating Temperature

-45℃~+60℃

IV. Technical specifications

Installation form and position

Buried/surface

Box size

400*300*180mm

Bracket size

Φ88.9×221.4 mm

Explosion-proof type

Body explosion-proof

Shell protection grade

≥IP65

Shell anti-corrosion

Plastic spraying

Internal structure three-proof

Moisture-proof, salt spray-proof, bacteria-proof

Internal high current

connection cable

AGG-10kV Silicone Rubber High Voltage Cable

Voltage class

10kV

Insulation

Insulation resistance ≥100MΩ

Single-core multi-stranded

stranded copper conductor

25mm²


V. Installation instructions

1、Connect one end of the product to the pipeline and one end to the grounding network,

and the grounding resistance value of the grounding network should be controlled within 4 ohms.

2、This product can be installed in explosion-proof environment by adopting explosion-proof

box structure.

3、This product adopts sealed structure and can be installed in wet place.

 

VI. Maintenance

This product is a maintenance-free product, but in the event of direct lightning and other strong current impacts increase in the number of times (more than 15 times), the product will have the possibility of deterioration, deterioration that is, the product is damaged and out of action.

 The product should be opened periodically to check the resistance of the product terminals at both ends, if the resistance value of the ohm level, the product should be overhauled or replaced in a timely manner.